NIRI
Executive report
11/11/2026
Illustrative demonstration · synthetic data

Mutual Energy
Executive resilience report

Mutual Energy management · aggregated portfolio information only

Selected scenario and system consequence

30-day compound failure — Moyle unavailable, 2 generating units unavailable, 30 days, winter peak, low wind.

Indicative margin -510 MW (-7.5%) · Severe

This simplified screening model is not an electrical network simulation or blackout forecast.

Executive findings

  1. Mutual Energy own risk: Moyle unavailable for 30 days creates an illustrative £11.3m cash-flow sensitivity, separate from downstream losses.
  2. Electricity system: indicative resources are 6,290 MW against 6,800 MW demand, giving severe screening stress; this is not a blackout forecast.
  3. Downstream economy: 20 of 20 fictional businesses have potential exposure under explicit site-interruption assumptions, with £269.7m high-case gross economic exposure.
  4. Portfolio accumulation: 20 exposed insured businesses share island electricity system; aggregated potential insured exposure is £102.0m.
  5. Decision priority: faster restoration reduces duration-driven consequences; insurance or alternative financing addresses residual financial exposure and does not improve physical resilience.

Asset, dependencies and restoration

Moyle Interconnector · Scotland–Northern Ireland · rated technical capacity 500 MW. Rated capacity is not current available capacity or flow.

  • Validate asset condition, failure mode, protection and control-system evidence.
  • Confirm critical spares, specialist contractor mobilisation and repair access assumptions.
  • Coordinate alternative imports, generation, storage and demand response with responsible third parties.
  • Restoration is a selected assumption, not an automatically generated engineering forecast.

Mutual Energy own financial sensitivity

Synthetic assumptions only. Debt service sensitivity is 15× a £750k reference, not a credit rating, covenant compliance test or investment recommendation.

Downstream and portfolio accumulation

Downstream monetary severity is deliberately calibrated to approximately £100m insured exposure for the 30-day compound demonstration. Assumed loss amounts and policy limits are scaled 80×; this is not a validated forecast or a change to physical outage assumptions.

Gross economic exposure£269.7m

Potential downstream economic consequence before insurance

Potential insured exposure£102.0m

Simplified portfolio estimate; policy wording not verified

Uninsured / retained exposure£167.7m

Residual economic exposure after illustrative insured estimate

20 of 20 fictional businesses potentially exposed · 20 potential correlated claims. Common dependency: Island electricity system (20 businesses).

Mitigation and residual risk financing

OptionRestorationSystem stressPotential transferResidual retained + cost
No additional intervention30 daysSevere£0£11.3m
Engineering / operational mitigation7 daysSevere£0£8.57m
Mitigation + financial risk transfer7 daysSevere£3.30m£5.28m

Mitigation changes assumed physical and operational outcomes. Insurance, retention and alternative financing allocate residual financial consequences; they do not improve physical resilience.

Assumptions and limitations

  • All businesses, financial assumptions, loss estimates and portfolio outputs are fictional and illustrative.
  • System stress, site interruption, business consequence and economic loss are separate model stages.
  • No actual power flows, network constraints, dispatch, load shedding, engineering forecasts or claims are modelled.
  • Actual financial and insured losses require verified financial records, engineering evidence and policy wording.